3. REMOVE VOLTAGE REGULATOR

Remove the 3 screws and voltage regulator.

4. REMOVE RECTIFIER HOLDER

a. 70 A type:

Remove the 4 screws, bolt and rectifier holder. 

b. 80 A type:

Remove the 4 screws and rectifier holder. 

c. 80 A type:

Remove the 4 rubber insulators.

5. REMOVE PULLEY

a. Hold SST (A) with a torque wrench, and tighten SST (B) clockwise to the specified torque.

SST 09820-63011

Torque: 39 Nm (400 kg.cm, 29 ft.lb)

b. Check that SST (A) is secured to the rotor shaft.