Tundra Access Cab SR5 2WD V8-4.7L (2UZ-FE) (2001)
Audible Warning Device Control Module: Testing and Inspection
LIGHT AUTO TURN OFF
HEAD RELAY
2 - 1 : Closed with the light control SW at HEAD position or the dimmer SW at FLASH position.
Closed with the engine running and the parking brake lever released (w/ daytime running light)
C15 LIGHT CONTROL SW [COMB. SW]
13 - 16
: Closed with light control SW at HEAD position
14 - 16
: Closed with light control SW at TAIL or HEAD position
D16 DOOR COURTESY SW FRONT LH
1 - GROUND : Continuity with the front LH door open
INTEGRATION RELAY
9 - GROUND
: Approx. 12 volts with the ignition SW at ON position
14 - GROUND
: Continuity with the front LH door open
3, 6 - GROUND : Always approx. 12 volts
8 - GROUND
: Always continuity
POWER WINDOW
D16, D17 DOOR COURTESY SW LH, RH
1 - GROUND : Continuity with door open
INTEGRATION RELAY
9 - GROUND
: Approx. 12 volts with ignition SW at ON position
3 - GROUND
: Always approx. 12 volts
14 - GROUND
: Continuity with front LH door open (Standard cab)
14 - GROUND
: Continuity with each LH door open (Access cab)
15 - GROUND
: Continuity with front RH door open (Standard cab)
15 - GROUND
: Continuity with each RH door open (Access cab)
P9 POWER WINDOW CONTROL SW RH
4 - GROUND : Approx. 12 volts with ignition SW on and stays at 12 volts for 41.5 - 44.5 seconds after the ignition SW is turned off, but if a door is
open in the 45 seconds period, voltage will drop to 0 volts
P10 POWER WINDOW MASTER SW
1 - GROUND : Always continuity
9 - GROUND : Approx. 12 volts with ignition SW on and stays at 12 volts for 41.5 - 44.5 seconds after the ignition SW is turned off, but if a door is
opened in this 41.5 - 44.5 seconds period, voltage will drop to 0 volts
3 - GROUND : Approx. 12 volts with ignition SW at ON position and master SW at UP position
4 - GROUND : Approx. 12 volts with ignition SW at ON position and master SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with window lock SW at LOCK position
DOOR LOCK CONTROL
INTEGRATION RELAY
8 - GROUND
: Always continuity
3 - GROUND
: Always approx. 12 volts