b. 70 A type:

Place the voltage regulator together with the brush holder horizontally on the rectifier end frame.

c. 70 A type:

Install the 5 screws until there is a clearance of approx. 1 mm (0.04 in.) between the brush holder and voltage regulator.

Torque: 1.96 Nm (20 kg.cm, 17 in.lb)

d. 70 A type:

Fit the brush holder cover.

e. 100 A type:

Place the seal plate on the rectifier end frame.