Checking and Adjustment Values
Engine
|
|
X 20 DTL
|
Y 20 DTL, Y 20 DTH
|
Idle speed
|
|
|
|
with manual transmission
|
rpm
|
760 – 860
1)
|
1)
|
|
with automatic transmission
|
rpm
|
760 – 860
1)
|
1)
|
Cut off speed
|
rpm
|
4750
1)
|
5000 ± 50
1)
|
Exhaust gas opacity value
|
rpm
|
1.7
|
Compression
|
kPa
|
2500 – 2800
2)
|
Pressure loss
|
|
not more than 25% per cylinder
|
Valve play
|
mm
|
0
|
Engine
|
|
Y 22 DTR
|
Idle speed
|
|
|
|
with manual transmission
|
rpm
|
1)
|
Cut off speed
|
rpm
|
4220 - 5080
|
Exhaust gas opacity value
|
rpm
|
1.7
|
Compression
|
kPa
|
2500 - 2800
2)
|
Pressure loss
|
|
not more than 25% per cylinder
|
Valve play
|
mm
|
0
|
1 ) Correction and checking according to Checking
Procedure with TECH 2.
2 ) The pressure difference between individual
cylinders should not exceed 100 kPa.
|