Remove air intake hose with hot film mass air flow meter.
Disconnect wiring harness plug (2) and vacuum hoses (1).
Detach charge pressure control solenoid valve (3) from
bracket.
Install
Attach charge pressure control solenoid valve to wheel well
– tightening torque 4 Nm / 3 lbf. ft.
Attach wiring harness plug and vacuum hoses.
Install air intake hoses with hot film mass air flow meter
– tightening torque 3.5 Nm / 2.6 lbf. ft.
|