Reference Gap between Crankshaft Pulse Pick-up and Increment Disc, Check
Measure
Measure distance between crankshaft pulse pickup and increment disc with feeler gauge.
Nominal value: 1.0 ± 0.7 mm.
With incorrect gap – replace bracket for crankshaft pulse pickup.
Torque
Crankshaft pulse pick-up bracket to oil pump – 10 Nm / 7 lbf. ft.