vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Coolant Flange (DIS Ignition Module Adapter), Remove and Install > < Fuel Pump Relay, Remove and Install

Oxygen Sensor, Remove and Install (X 18 XE1)

Caution

Remove oxygen sensor only with engine at operating temperature.

  Remove

Disconnect wiring harness plug (1) for oxygen sensor. Unscrew oxygen sensor (2) from front exhaust pipe.

Caution

When re-using the oxygen sensor, coat thread of oxygen sensor with special grease (black). Ensure correct cable routing – route cable of oxygen sensor so that abrasion does not occur and it does not touch the exhaust pipe.

  Install

Screw oxygen sensor in exhaust pipe – tightening torque 40 Nm / 29.5 lbf. ft.

Connect wiring harness plug (1) for oxygen sensor.

Object Number: 2398403  Size: DEFAULT