Coolant Pump, Remove and Install
Remove
Open coolant drain bolt – collect escaping coolant.
Remove air cleaner housing with air intake cover – see
illustration "Air Ducts (X 16 SZR)" and illustration "Air Ducts (Z
16 SE)".
Remove upper part of toothed belt cover – see operation
"Toothed Belt Cover – Upper Part, Remove and Install".
Remove ribbed V-belts – see operation "Ribbed V-belts,
Remove and Install".
Remove ribbed V-belt tensioner – see operation "Ribbed
V-belt Tensioner, Remove and Install".
Remove lower part of toothed belt cover – see operation
"Toothed Belt Cover – Lower Part, Remove and Install".
Remove toothed belt – see operation "Toothed Belt, Remove
and Install".
Remove toothed belt tension roller – see operation
"Toothed Belt Tension Roller, Remove and Install".
Remove rear toothed belt cover – see operation "Rear
Toothed Belt Cover, Remove and Install". Remove fastening bolts (3)
from coolant pump and remove coolant pump.
Clean
Remove gasket residues and clean sealing surfaces.
Install
Before installing coolant pump, coat sealing surface (4) with
silicon grease (white).
Attach coolant pump with new seal ring to cylinder block –
tightening torque 8 Nm / 6 lbf. ft.
Mark (1) on cylinder block must align with mark (2) on coolant
pump.
Install rear toothed belt cover – see operation "Toothed
Belt Cover – Rear, Remove and Install".
|
|
Install toothed belt tension roller – see operation
"Toothed Belt Tension Roller, Remove and Install".
Install toothed belt – see operation "Toothed Belt, Remove
and Install".
Install lower part of toothed belt cover – see operation
"Toothed Belt Cover – Lower Part, Remove and Install".
Install ribbed V-belt tensioner – see operation "Ribbed
V-belt Tensioner, Remove and Install".
Install ribbed V-belt – see operation "Ribbed V-belt,
Remove and Install".
Install upper part of toothed belt cover – see operation
"Toothed Belt Cover – Upper Part, Remove and Install".
Install air cleaner housing with air intake cover – see
illustration "Air Ducts (X 16 SZR)" and illustration "Air Ducts (Z
16 SE)".
Close coolant drain bolt.
Inspect
Charge cooling system – see operations "Cooling System,
Charge and Bleed" and "Cooling System, Check for Leaks".
|