Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A1_A14 Control Unit - Climate Control (Wiring Harness Connector XC43 )
- Ignition ON
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 25 (XC43) & Ground
|
less than 0.3 V
|
|
|
T002
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 25 (XC43) & Ground
|
greater than 500 kOhm
|
|
|
T003
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 25 (XC43) & A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 23 (XC43)
|
20 ... 65 kOhm
The given nominal value is valid for a temperature range from 10 °C (50 °F) to 30 °C (86 °F).
|
|
|
T004
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 25 (XC43) & A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 23 (XC43)
|
less than 20 kOhm
The given nominal value is valid for a temperature range from 10 °C (50 °F) to 30 °C (86 °F).
|
|
|
T005
|
Check: Interruption in Wiring Harness
|
- Disconnect wiring harness connector from:
B3_A14 Sensor - Temperature, Evaporator
- Measure resistance between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 25 (XC43) & B3_A14 Sensor - Temperature, Evaporator Wiring harness connector (wiring harness side) terminal A
|
less than 5 Ohm
|
|
|