Servo Motor – Mixed Air Valve, Remove and
Install (RHD)
Remove
1. |
Disconnect battery.
Note: Only upon
replacement of servo motor.
|
|
2. |
Remove glove compartment
• |
Separate wiring harness plug
|
|
3. |
Remove inner panelling footwell passenger's side
|
4. |
Remove passenger's side footwell air duct
• |
Remove body-bound rivet (3)
|
|
|
|
5. |
Remove servo motor mixed air valve (1)
• |
Unscrew 3x bolt (arrows)
|
• |
Separate wiring harness plug (2)
– |
Release and disconnect wiring harness plug
|
|
|
|
Install
6. |
Attach servo motor mixed air valve
Note: The servo motor
can only be fitted in one position.
• |
Connect wiring harness plug.
|
|
7. |
Install passenger's side footwell air duct
• |
Install body-bound rivet
|
|
8. |
Install inner panelling footwell passenger's side
|
9. |
Install glove compartment
• |
Connect wiring harness plug.
|
|
10. |
Connect battery.
Note: Only upon
replacement of servo motor.
|
11. |
Program volatile memories
Note: Only upon
replacement of servo motor.
|
12. |
Perform function check
|
|