vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

C-002 Radiator Coolant Temperature Sensor Circuit > < B-009 No Matching Customer Complaint

C-001 - Engine Coolant Temperature Sensor Circuit

Test

Work Order Description

Nominal Value

T001

Check: Vehicle Configuration

Is the following information correct for the actual vehicle?

Z 16 XEP
Z 16 XE1
Yes: No:
T002

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    FE6 Fuse
  • Disconnect wiring harness connector from:
    B39B Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
    &
    Ground

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T003

Check: Component

  • Diagnostic Tester Data List Parameter
    Coolant Temperature

4.8 ... 5.2 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T004

Check: Short to Voltage/Interruption of Ground Circuit

  • Connect fused jumper wire to:
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1
    &
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
  • Diagnostic Tester Data List Parameter
    Coolant Temperature

less than 0.3 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T005

Check: Short to Voltage/Interruption of Ground Circuit

  • Do not remove fused jumper wire
  • Ignition OFF
  • Disconnect wiring harness connector from:
    Y56 Solenoid Valve - Exhaust Gas Recirculation
  • Ignition ON
  • Diagnostic Tester Data List Parameter
    Coolant Temperature

less than 0.3 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T006

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    FE6 Fuse
  • Disconnect wiring harness connector from:
    B39B Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
    &
    Ground

greater than 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T007

Check: Vehicle Configuration

Is the following information correct for the actual vehicle?

Z 18 XER
Z 16 XER
Yes: No:
T008

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    (Astra-H), (Z 18 XER), (Air Conditioning (not ECC)), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Electronic Climate Control ECC), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Automatic Climate Control SAC), (Front Wheel Drive, Automatic Transmission, AF 17-4) FE5, FE6 (Astra-H), (Z 18 XER) (Astra-H), (Z 16 XER) FE6 Fuse
  • Disconnect wiring harness connector from:
    B39A Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1
    &
    Ground
(Astra-H), (Z 18 XER), (Air Conditioning (not ECC)), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Electronic Climate Control ECC), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Automatic Climate Control SAC), (Front Wheel Drive, Automatic Transmission, AF 17-4)

4.8 ... 5.2 V

(Astra-H), (Z 18 XER) (Astra-H), (Z 16 XER)

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T009

Check: Component

  • Diagnostic Tester Data List Parameter
    Coolant Temperature

4.8 ... 5.2 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T010

Check: Short to Voltage of Ground Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    A84 Control Unit - Engine
  • Ignition ON
  • Measure voltage between the following terminals:
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
    &
    Ground

less than 0.3 V

Voltage Measurement Current Value: V
Yes: No:
T011

Check: Short to Ground of Signal Circuit

  • Ignition OFF
  • Measure resistance between the following terminals:
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
    &
    Ground

greater than 500 kOhm

Resistance Measurement Current Value: kOhm
Yes: No:
T012

Check: Circuit Interruption of Ground Circuit

  • Measure resistance between the following terminals:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Default) 25 (XC3) (Z 16 XER) 25 (XC101)
    &
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
Default

less than 5 Ohm

(Z 16 XER)

less than 5 Ohm

Resistance Measurement Current Value: Ohm
Yes: No:
T013

Check: Component

  • Connect wiring harness connector to:
    A84 Control Unit - Engine
  • Connect fused jumper wire to:
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1
    &
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
  • Ignition ON
  • Diagnostic Tester Data List Parameter
    Coolant Temperature

less than 0.3 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T014

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    (Astra-H), (Z 18 XER), (Air Conditioning (not ECC)), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Electronic Climate Control ECC), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Automatic Climate Control SAC), (Front Wheel Drive, Automatic Transmission, AF 17-4) FE5, FE6 (Astra-H), (Z 18 XER) (Astra-H), (Z 16 XER) FE6 Fuse
  • Disconnect wiring harness connector from:
    B39A Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1
    &
    Ground
(Astra-H), (Z 18 XER), (Air Conditioning (not ECC)), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Electronic Climate Control ECC), (Front Wheel Drive, Automatic Transmission, AF 17-4) (Astra-H), (Z 18 XER), (Automatic Climate Control SAC), (Front Wheel Drive, Automatic Transmission, AF 17-4)

greater than 5.2 V

(Astra-H), (Z 18 XER) (Astra-H), (Z 16 XER)

greater than 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T015

Check: Vehicle Configuration

Is the following information correct for the actual vehicle?

Z 22 YH
Yes: No:
T016

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    (Default) FE6 (Astra-H), (Air Conditioning (not ECC)) (Astra-H), (Electronic Climate Control ECC) (Astra-H), (Automatic Climate Control SAC) FE5, FE6 Fuse
  • Disconnect wiring harness connector from:
    B39 Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal A
    &
    Ground
Default

4.8 ... 5.2 V

(Astra-H), (Air Conditioning (not ECC)) (Astra-H), (Electronic Climate Control ECC) (Astra-H), (Automatic Climate Control SAC)

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T017

Check: Component

  • Diagnostic Tester Data List Parameter
    Coolant Temperature

4.8 ... 5.2 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T018

Check: Short to Voltage/Interruption of Ground Circuit

  • Connect fused jumper wire to:
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Z 12 XEP) (Z 14 XEP) (Z 14 XEL) (Z 18 XE) (Z 20 LEH) (Z 20 LEL) (Z 20 LER) (Z 17 DTH) (Z 17 DTL) (Z 13 DTH) (Z 19 DT) (Z 19 DTH) (Z 19 DTL) (Z 17 DTJ) (Z 17 DTR) (Z 16 LET) (A 16 LET) (A 17 DTJ) (A 17 DTR) 1 (Z 22 YH) A
    &
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Z 12 XEP) (Z 14 XEP) (Z 14 XEL) (Z 18 XE) (Z 20 LEH) (Z 20 LEL) (Z 20 LER) (Z 17 DTH) (Z 17 DTL) (Z 13 DTH) (Z 19 DT) (Z 19 DTH) (Z 19 DTL) (Z 17 DTJ) (Z 17 DTR) (Z 16 LET) (A 16 LET) (A 17 DTJ) (A 17 DTR) 2 (Z 22 YH) B
  • Diagnostic Tester Data List Parameter
    Coolant Temperature
(Z 12 XEP) (Z 14 XEP) (Z 14 XEL) (Z 18 XE) (Z 20 LEH) (Z 20 LEL) (Z 20 LER) (Z 17 DTH) (Z 17 DTL) (Z 13 DTH) (Z 19 DT) (Z 19 DTH) (Z 19 DTL) (Z 17 DTJ) (Z 17 DTR) (Z 16 LET) (A 16 LET) (A 17 DTJ) (A 17 DTR)

less than 0.3 V

(Z 22 YH)

less than 0.3 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T019

Check: Vehicle Configuration

Is the following information correct for the actual vehicle?

Z 18 XE
Yes: No:
T020

Check: Short to Voltage/Interruption of Ground Circuit

  • Do not remove fused jumper wire
  • Ignition OFF
  • Disconnect wiring harness connector from:
    B28 Sensor - Camshaft
  • Ignition ON
  • Diagnostic Tester Data List Parameter
    Coolant Temperature

less than 0.3 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T021

Check: Vehicle Configuration

Is the following information correct for the actual vehicle?

Z 22 YH
Yes: No:
T022

Check: Short to Voltage/Interruption of Ground Circuit

  • Do not remove fused jumper wire
  • Ignition OFF
  • Disconnect wiring harness connector from:
    B54 Sensor - Fuel Pressure
  • Ignition ON
  • Diagnostic Tester Data List Parameter
    Coolant temperature
  • Disconnect each of the following components/control units consecutively from the wiring harness and repeat the check each time:
    B67 Sensor - Absolute Pressure, Intake Manifold
    B57 Sensor - Oxygen, Catalytic Converter Check
    B28 Sensor - Camshaft
    Y56 Solenoid Valve - Exhaust Gas Recirculation
    Y145 Solenoid Valve - Swirl

less than 0.3 V

Voltage Measurement Current Value: V
Yes: No:
T023

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    (Default) FE6 (Astra-H), (Air Conditioning (not ECC)) (Astra-H), (Electronic Climate Control ECC) (Astra-H), (Automatic Climate Control SAC) FE5, FE6 Fuse
  • Disconnect wiring harness connector from:
    B39 Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal A
    &
    Ground
Default

greater than 5.2 V

(Astra-H), (Air Conditioning (not ECC)) (Astra-H), (Electronic Climate Control ECC) (Astra-H), (Automatic Climate Control SAC)

greater than 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T024

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    (Default) FE6 (Z 14 XEL), (Air Conditioning (not ECC)) (Z 14 XEL), (Electronic Climate Control ECC) (Z 14 XEP), (Air Conditioning (not ECC)) (Z 14 XEP), (Electronic Climate Control ECC) (Z 18 XE), (Air Conditioning (not ECC)) (Z 18 XE), (Electronic Climate Control ECC) (Z 20 LEL) (Z 20 LER) (Z 17 DTL), (Air Conditioning (not ECC)) (Z 17 DTL), (Electronic Climate Control ECC) (Z 17 DTH) (Z 19 DTH) (Z 12 XEP), (Air Conditioning (not ECC)) (Z 12 XEP), (Electronic Climate Control ECC) (Z 20 LEH) (Z 19 DT) (Z 19 DTL) (Z 17 DTL), (Automatic Climate Control SAC) (Z 13 DTH), (Air Conditioning (not ECC)) (Z 13 DTH), (Electronic Climate Control ECC) (Z 13 DTH), (Automatic Climate Control SAC) (Z 16 LET), (Air Conditioning (not ECC)) (Z 16 LET), (Electronic Climate Control ECC) (Z 16 LET), (Automatic Climate Control SAC) (Z 17 DTJ) (Z 17 DTR) (A 16 LET), (Air Conditioning (not ECC)) (A 16 LET), (Electronic Climate Control ECC) (A 16 LET), (Automatic Climate Control SAC) (A 17 DTJ) (A 17 DTR) FE5, FE6 Fuse
  • Disconnect wiring harness connector from:
    B39 Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1
    &
    Ground
Default

4.8 ... 5.2 V

(Z 14 XEL), (Air Conditioning (not ECC)) (Z 14 XEL), (Electronic Climate Control ECC) (Z 14 XEP), (Air Conditioning (not ECC)) (Z 14 XEP), (Electronic Climate Control ECC) (Z 18 XE), (Air Conditioning (not ECC)) (Z 18 XE), (Electronic Climate Control ECC) (Z 20 LEL) (Z 20 LER) (Z 17 DTL), (Air Conditioning (not ECC)) (Z 17 DTL), (Electronic Climate Control ECC) (Z 17 DTH) (Z 19 DTH) (Z 12 XEP), (Air Conditioning (not ECC)) (Z 12 XEP), (Electronic Climate Control ECC) (Z 20 LEH) (Z 19 DT) (Z 19 DTL) (Z 17 DTL), (Automatic Climate Control SAC) (Z 13 DTH), (Air Conditioning (not ECC)) (Z 13 DTH), (Electronic Climate Control ECC) (Z 13 DTH), (Automatic Climate Control SAC) (Z 16 LET), (Air Conditioning (not ECC)) (Z 16 LET), (Electronic Climate Control ECC) (Z 16 LET), (Automatic Climate Control SAC) (Z 17 DTJ) (Z 17 DTR) (A 16 LET), (Air Conditioning (not ECC)) (A 16 LET), (Electronic Climate Control ECC) (A 16 LET), (Automatic Climate Control SAC) (A 17 DTJ) (A 17 DTR)

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T025

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    (Default) FE6 (Z 14 XEL), (Air Conditioning (not ECC)) (Z 14 XEL), (Electronic Climate Control ECC) (Z 14 XEP), (Air Conditioning (not ECC)) (Z 14 XEP), (Electronic Climate Control ECC) (Z 18 XE), (Air Conditioning (not ECC)) (Z 18 XE), (Electronic Climate Control ECC) (Z 20 LEL) (Z 20 LER) (Z 17 DTL), (Air Conditioning (not ECC)) (Z 17 DTL), (Electronic Climate Control ECC) (Z 17 DTH) (Z 19 DTH) (Z 12 XEP), (Air Conditioning (not ECC)) (Z 12 XEP), (Electronic Climate Control ECC) (Z 20 LEH) (Z 19 DT) (Z 19 DTL) (Z 17 DTL), (Automatic Climate Control SAC) (Z 13 DTH), (Air Conditioning (not ECC)) (Z 13 DTH), (Electronic Climate Control ECC) (Z 13 DTH), (Automatic Climate Control SAC) (Z 16 LET), (Air Conditioning (not ECC)) (Z 16 LET), (Electronic Climate Control ECC) (Z 16 LET), (Automatic Climate Control SAC) (Z 17 DTJ) (Z 17 DTR) (A 16 LET), (Air Conditioning (not ECC)) (A 16 LET), (Electronic Climate Control ECC) (A 16 LET), (Automatic Climate Control SAC) (A 17 DTJ) (A 17 DTR) FE5, FE6 Fuse
  • Disconnect wiring harness connector from:
    B39 Sensor - Temperature, Coolant
  • Ignition ON
  • Measure voltage between the following terminals:
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1
    &
    Ground
Default

greater than 5.2 V

(Z 14 XEL), (Air Conditioning (not ECC)) (Z 14 XEL), (Electronic Climate Control ECC) (Z 14 XEP), (Air Conditioning (not ECC)) (Z 14 XEP), (Electronic Climate Control ECC) (Z 18 XE), (Air Conditioning (not ECC)) (Z 18 XE), (Electronic Climate Control ECC) (Z 20 LEL) (Z 20 LER) (Z 17 DTL), (Air Conditioning (not ECC)) (Z 17 DTL), (Electronic Climate Control ECC) (Z 17 DTH) (Z 19 DTH) (Z 12 XEP), (Air Conditioning (not ECC)) (Z 12 XEP), (Electronic Climate Control ECC) (Z 20 LEH) (Z 19 DT) (Z 19 DTL) (Z 17 DTL), (Automatic Climate Control SAC) (Z 13 DTH), (Air Conditioning (not ECC)) (Z 13 DTH), (Electronic Climate Control ECC) (Z 13 DTH), (Automatic Climate Control SAC) (Z 16 LET), (Air Conditioning (not ECC)) (Z 16 LET), (Electronic Climate Control ECC) (Z 16 LET), (Automatic Climate Control SAC) (Z 17 DTJ) (Z 17 DTR) (A 16 LET), (Air Conditioning (not ECC)) (A 16 LET), (Electronic Climate Control ECC) (A 16 LET), (Automatic Climate Control SAC) (A 17 DTJ) (A 17 DTR)

greater than 5.2 V

Voltage Measurement Current Value: V
Yes: No:


Result

Cause Of Fault

E001 Result: Defective Component
  • Defective component:
    B39B Sensor - Temperature, Coolant
E002 Result: Defective Component

If the nominal value is reached during one of the measurements, there is a short to voltage in the circuit behind the component that has been disconnected immediately before that measurement, or the corresponding component is defective.

E003 Result: Short to Voltage/Interruption
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 62 (XC9)
    &
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Default) 2 (Z 16 XE1) 1
    &
    Y56 Solenoid Valve - Exhaust Gas Recirculation
    Wiring harness connector (wiring harness side) terminal C

or

  • Circuit interruption between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 62 (XC9)
    &
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Default) 2 (Z 16 XE1) 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E004 Result: Defective Component
  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E005 Result: Short to Voltage
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 10 (XC9)
    &
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Astra-H), (Z 16 XE1) 2 (Astra-H), (Z 16 XEP) 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E006 Result: Short to Ground/Interruption
  • Short circuit to ground/interruption of circuit between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 10 (XC9)
    &
    B39B Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Astra-H), (Z 16 XE1) 2 (Astra-H), (Z 16 XEP) 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E007 Result: Defective Component
  • Defective component:
    B39A Sensor - Temperature, Coolant
E008 Result: Defective Component
  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E009 Result: Interruption
  • Circuit interruption between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Default) 25 (XC3) (Z 16 XE1) 25 (XC101)
    &
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
E010 Result: Short to Ground
  • Short circuit to ground between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Default) 25 (XC3) (Z 16 XER) 25 (XC101)
    &
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
E011 Result: Short to Voltage
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Default) 25 (XC3) (Z 16 XER) 25 (XC101)
    &
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 2
E012 Result: Short to Voltage
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Astra-H), (Z 16 XER) 60 (XC101) (Astra-H), (Z 18 XER) 60 (XC3)
    &
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E013 Result: Short to Ground/Interruption
  • Short circuit to ground/interruption of circuit between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Astra-H), (Z 16 XER) 60 (XC101) (Astra-H), (Z 18 XER) 60 (XC3)
    &
    B39A Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E014 Result: Defective Component
  • Defective component:
    B39 Sensor - Temperature, Coolant
E015 Result: Short to Voltage/Interruption
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Z 14 XEL) (Z 14 XEP) (Z 12 XEP) 42 (XC1) (Z 18 XE) 1 (XC3) (Z 20 LEL) (Z 20 LER) (Z 20 LEH) 42 (XC7) (Z 17 DTL) (Z 17 DTH) 41 (XC11) (Z 19 DTH) (Z 19 DT) (Z 19 DTL) 41 (XC52) (Z 13 DTH) 29 (XC19) (Z 16 LET) (A 16 LET) 42 (XC99) (Z 22 YH) 43 (XC54) (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 7 (XC97)
    &
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Z 14 XEL) (Z 14 XEP) (Z 12 XEP) 2 (Z 18 XE) 2 (Z 20 LEL) (Z 20 LER) (Z 20 LEH) 2 (Z 17 DTL) (Z 17 DTH) 2 (Z 19 DTH) (Z 19 DT) (Z 19 DTL) 2 (Z 13 DTH) 2 (Z 16 LET) (A 16 LET) 2 (Z 22 YH) B (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 2
    &
    Wiring harness connector terminals of all components (wiring harness side), which were disconnected from the wiring harness during this troubleshooting session

or

  • Circuit interruption between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Z 14 XEL) (Z 14 XEP) (Z 12 XEP) 42 (XC1) (Z 18 XE) 1 (XC3) (Z 20 LEL) (Z 20 LER) (Z 20 LEH) 42 (XC7) (Z 17 DTL) (Z 17 DTH) 41 (XC11) (Z 19 DTH) (Z 19 DT) (Z 19 DTL) 41 (XC52) (Z 13 DTH) 29 (XC19) (Z 16 LET) (A 16 LET) 42 (XC99) (Z 22 YH) 43 (XC54) (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 7 (XC97)
    &
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Z 14 XEL) (Z 14 XEP) (Z 12 XEP) 2 (Z 18 XE) 2 (Z 20 LEL) (Z 20 LER) (Z 20 LEH) 2 (Z 17 DTL) (Z 17 DTH) 2 (Z 19 DTH) (Z 19 DT) (Z 19 DTL) 2 (Z 13 DTH) 2 (Z 16 LET) (A 16 LET) 2 (Z 22 YH) B (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 2

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E016 Result: Short to Voltage
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Z 14 XEP) (Z 14 XEL) (Z 12 XEP) 38 (XC1) (Z 18 XE) 25 (XC3) (Z 20 LEL) (Z 20 LER) 38 (XC7) (Z 19 DTH) 58 (XC52) (Z 17 DTH) (Z 17 DTL) 58 (XC11) (Z 13 DTH) 54 (XC19) (Z 16 LET) (A 16 LET) 38 (XC99) (Z 22 YH) 60 (XC54) (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 31 (XC97)
    &
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Z 14 XEP) (Z 14 XEL) (Z 12 XEP) 1 (Z 18 XE) 1 (Z 20 LEL) (Z 20 LER) 1 (Z 19 DTH) 1 (Z 17 DTH) (Z 17 DTL) 1 (Z 13 DTH) 1 (Z 16 LET) (A 16 LET) 1 (Z 22 YH) A (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E017 Result: Short to Ground/Interruption
  • Short circuit to ground/interruption of circuit between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal (Z 14 XEL) (Z 14 XEP) (Z 12 XEP) 38 (XC1) (Z 18 XE) 25 (XC3) (Z 20 LEL) (Z 20 LER) 38 (XC7) (Z 17 DTL) (Z 17 DTH) 58 (XC11) (Z 19 DTH) 58 (XC52) (Z 13 DTH) 54 (XC19) (Z 16 LET) (A 16 LET) 38 (XC99) (Z 22 YH) 60 (XC54) (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 31 (XC97)
    &
    B39 Sensor - Temperature, Coolant
    Wiring harness connector (wiring harness side) terminal (Z 14 XEL) (Z 14 XEP) (Z 12 XEP) 1 (Z 18 XE) 1 (Z 20 LEL) (Z 20 LER) 1 (Z 17 DTL) (Z 17 DTH) 1 (Z 19 DTH) 1 (Z 13 DTH) 1 (Z 16 LET) (A 16 LET) 1 (Z 22 YH) A (Z 17 DTJ) (Z 17 DTR) (A 17 DTJ) (A 17 DTR) 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.






C-002 Radiator Coolant Temperature Sensor Circuit > < B-009 No Matching Customer Complaint