Actuating Drive, Change-Over Valves, Remove and
Install
Remove
1. |
Remove oil separator/vacuum reservoir bracket
|
2. |
Remove actuating drive, change-over valves (3)
• |
Disconnect linkage (2) with KM-6042
|
• |
Unscrew 2x stud bolt (1)
|
• |
Disconnect wiring harness connector.
|
|
|
|
Install
3. |
Install actuating drive for change-over valves
• |
Fix wiring harness plug
|
• |
Attach linkage carefully
|
|
4. |
Install oil separator/vacuum reservoir bracket
|
|