Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
Disconnect wiring harness connector from: B69 Air Mass Meter
- Ignition ON
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 1 & Ground
|
4.8 ... 5.2 V
|
|
|
T002
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 2 & Ground
|
less than 0.3 V
|
|
|
T003
|
Check: Component
|
- Diagnostic Tester Data List Parameter
Intake Air Temperature
|
4.8 ... 5.2 V
|
|
|
T004
|
Check: Interruption of Signal Circuit
|
- Connect fused jumper wire to:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 1 & B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 2
- Diagnostic Tester Data List Parameter
Intake Air Temperature
|
less than 0.3 V
|
|
|
T005
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
Disconnect wiring harness connector from: B69 Air Mass Meter
- Ignition ON
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 1 & Ground
|
greater than 5.2 V
|
|
|