Result
|
Cause Of Fault
|
E001
|
Result: Defective Component
|
- Defective component:
A84 Control Unit - Engine
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E002
|
Result: Defective Component
|
- Circuit interruption between:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 28 (XC3) & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 50 (XC55)
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E003
|
Result: Defective Component
|
- Circuit interruption between:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 28 (XE3) & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 33 (XC55)
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E004
|
Result: Defective Component
|
- Circuit interruption between:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 28 (XE3) & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 18 (XC55)
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E005
|
Result: Defective Component
|
- Defective component:
K2_X125 Relay - Engine Control Unit
|
|
E006
|
Result: Defective Component
|
- Circuit interruption between:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 28 (XE3) & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 1 (XC55)
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E007
|
Result: Defective Component
|
- Defective component:
K2_X125 Relay - Engine Control Unit
|
|
E008
|
Result: Defective Component
|
- Short circuit to ground/interruption of circuit between:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 16 (XE3) & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 37 (XC55)
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E009
|
Result: Short to Voltage
|
- Short circuit to voltage between:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 37 (XC55) & K2_X125 Relay - Engine Control Unit Socket Terminal 85
or
- Defective component:
A84 Control Unit - Engine
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E010
|
Result: Interruption
|
- Circuit interruption between:
G1 Battery Wiring harness connector (wiring harness side) terminal 30 & X125 Underhood Electronic Module Wiring harness connector (wiring harness side) wiring colour RD
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
Note:
Wiring colours: BK=Black, BN=Brown, BU=Blue, GD=Gold, GN=Green, GY=Grey, OG=Orange, PK=Pink, RD=Red, SR=Silver, TQ=Turquoise, VT=Violet, WH=White, YE=Yellow, L=Light, D=Dark
|
|