Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
Y56 Solenoid Valve - Exhaust Gas Recirculation
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2 & Ground
|
4.8 ... 5.2 V
|
|
|
T002
|
Check: Short to Voltage/Interruption of Ground Circuit
|
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2 & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4
|
4.8 ... 5.2 V
|
|
|
T003
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC54 )
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 6 & Ground
|
less than 0.3 V
|
|
|
T004
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 6 & Ground
|
greater than 500 kOhm
|
|
|
T005
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 58 (XC54) & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 6
|
less than 5 Ohm
|
|
|
T006
|
Check: Short to Voltage of Signal Circuit
|
- Connect wiring harness connector to:
A84 Control Unit - Engine
- Connect fused jumper wire to:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2 & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 6
- Ignition ON
- Diagnostic Tester Data List Parameter
EGR Position Feedback (Exhaust Gas Recirculation)
Note:
This data list parameter is in the data list 2 .
|
4.8 ... 5.2 V
|
|
|
T007
|
Check: Short to Ground/Interruption of Signal Circuit
|
- Ignition OFF
- Remove fused jumper wire
- Connect fused jumper wire to:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 6 & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4
- Ignition ON
- Diagnostic Tester Data List Parameter
EGR Position Feedback (Exhaust Gas Recirculation)
Note:
This data list parameter is in the data list 2 .
|
less than 0.3 V
|
|
|
T008
|
Check: Circuit Interruption of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 5 & Ground
|
less than 0.3 V
|
|
|
T009
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 23 (XC54) & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 1
|
less than 5 Ohm
|
|
|
T010
|
Check: Short to Voltage of Voltage Supply Circuit
|
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 1 & Ground
|
less than 0.3 V
|
|
|
T011
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 1 & Ground
|
greater than 500 kOhm
|
|
|
T012
|
Check: Interruption of Voltage Supply Circuit
|
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 7 (XC54) & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 5
|
less than 5 Ohm
|
|
|
T013
|
Check: Short to Ground of Voltage Supply Circuit
|
- Measure resistance between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 5 & Ground
|
greater than 500 kOhm
|
|
|
T014
|
Check: Short to Voltage of Ground Circuit
|
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4 & Ground
|
less than 0.3 V
|
|
|
T015
|
Check: Short to Voltage of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
Y145 Solenoid Valve - Swirl
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4 & Ground
- Disconnect each of the following components/control units consecutively from the wiring harness and repeat the measurement each time:
B28 Sensor - Camshaft B67 Sensor - Absolute Pressure, Intake Manifold B57 Sensor - Oxygen, Catalytic Converter Check B54 Sensor - Fuel Pressure B39 Sensor - Temperature, Coolant A84 Control Unit - Engine
|
less than 0.3 V
|
|
|
T016
|
Check: Vehicle Configuration
|
Is the following information correct for the actual vehicle?
Astra-H, Air Conditioning (not ECC) Astra-H, Electronic Climate Control ECC Astra-H, Automatic Climate Control SAC
|
|
|
T017
|
Check: Short to Voltage of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B18 Sensor - Pressure, Air Conditioning
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4 & Ground
|
less than 0.3 V
|
|
|
T018
|
Check: Vehicle Configuration
|
Is the following information correct for the actual vehicle?
Astra-H, Air Conditioning (not ECC) Astra-H, Electronic Climate Control ECC Astra-H, Automatic Climate Control SAC
|
|
|
T019
|
Check: Component
|
- Ignition OFF
- Disconnect wiring harness connector from:
B18 Sensor - Pressure, Air Conditioning
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2 & Ground
|
4.8 ... 5.2 V
|
|
|
T020
|
Check: Short to Voltage/Ground/Interruption of Voltage Supply
|
- Ignition OFF
- Disconnect wiring harness connector from:
Y145 Solenoid Valve - Swirl Ignition ON
- Measure voltage between:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2 & Ground
- Disconnect each of the following components/control units consecutively from the wiring harness and repeat the measurement each time:
B67 Sensor - Absolute Pressure, Intake Manifold B54 Sensor - Fuel Pressure
|
4.8 ... 5.2 V
|
|
|
T021
|
Check: Short to Voltage/Ground/Interruption of Voltage Supply
|
- Ignition OFF
- Disconnect wiring harness connector from:
Y145 Solenoid Valve - Swirl Ignition ON
- Measure voltage between:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2 & Ground
- Disconnect each of the following components/control units consecutively from the wiring harness and repeat the measurement each time:
B67 Sensor - Absolute Pressure, Intake Manifold B54 Sensor - Fuel Pressure
|
greater than 5.2 V
|
|
|