Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage/Ground of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B54 Sensor - Fuel Pressure
- Ignition ON
- Measure voltage between:
B54 Sensor - Fuel Pressure Wiring harness connector (wiring harness side) terminal 3 & Ground
|
4.8 ... 5.2 V
|
|
|
T002
|
Check: Circuit Interruption of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 43 (XC54) & B54 Sensor - Fuel Pressure Wiring harness connector (wiring harness side) terminal 1
|
less than 5 Ohm
|
|
|
T003
|
Check: Short to Voltage/Ground/Interruption of Signal Circuit
|
- Connect wiring harness connector to:
A84 Control Unit - Engine
- Ignition ON
- Measure voltage between the following terminals:
B54 Sensor - Fuel Pressure Wiring harness connector (wiring harness side) terminal 2 & Ground
|
4.8 ... 5.2 V
|
|
|
T004
|
Check: Component
|
- Diagnostic Tester Data List Parameter
Fuel Pressure Feedback
Note:
This data list parameter is in the data list 2 .
|
4.8 ... 5.2 V
|
|
|
T005
|
Check: Component
|
- Ignition OFF
- Connect fused jumper wire to:
B54 Sensor - Fuel Pressure Wiring harness connector (wiring harness side) terminal 2 & B54 Sensor - Fuel Pressure Wiring harness connector (wiring harness side) terminal 1
- Ignition ON
- Diagnostic Tester Data List Parameter
Fuel Pressure Feedback
Note:
This data list parameter is in the data list 2 .
|
less than 0.3 V
|
|
|