Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A112 Control Unit - Transmission (Wiring Harness Connector XC61 )
- Ignition ON
- Measure voltage between the following terminals:
A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 4 (XC61) & Ground
|
less than 0.3 V
|
|
|
T002
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 4 (XC61) & Ground
|
greater than 500 kOhm
|
|
|
T003
|
Check: Component
|
- Measure resistance between the following terminals:
A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 4 (XC61) & A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 9 (XC61)
Note:
Automatic transmission oil temperature between 15 °C (59 °F) and 25 °C (77 °F)
Temperature 20 °C (68 °F) : 5 ... 5.6 Ohm
|
5 ... 5.6 Ohm
|
|
|
T004
|
Check: Component
|
- Connect unfused jumper wire to:
A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 4 (XC61) & Ground
- Contact fused jumper wire once to:
A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 9 (XC61) & Battery voltage
|
Clicking noise from following component:
Y1_X121 Solenoid Valve Linear - Torque Converter Clutch
|
|
T005
|
Check: Component
|
- Measure resistance between the following terminals:
A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 4 (XC61) & A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 9 (XC61)
Note:
Automatic transmission oil temperature between 15 °C (59 °F) and 25 °C (77 °F)
Temperature 20 °C (68 °F) : 5 ... 5.6 Ohm
|
less than 5 Ohm
|
|
|