Overhaul supply unit (M20 MTA)
Remove
Important: Follow Easytronic
safety guidelines .
|
1. |
Remove supply unit
|
2. |
Detach hydraulic fluid reservoir (CS Speed oil)
• |
Unscrew 2x bolt (1)
Note: Note differing
bolt lengths
|
• |
Pull reservoir off of high-pressure pump
|
• |
Remove seal ring (2) from high-pressure pump
|
|
|
|
3. |
Detach electric motor
• |
Remove connecting sleeve (2) between motor and pump
|
|
|
|
4. |
Detach pressure reservoir (2)
• |
Clamp supply unit (1) into vice with protective jaws
|
• |
Remove pressure reservoir seal ring
|
|
|
|
Install
5. |
Attach pressure reservoir (2)
• |
Clamp supply unit (1) into vice with protective jaws
|
• |
Replace pressure reservoir seal ring
|
• |
Tighten pressure reservoir 80 Nm
|
|
|
|
6. |
Attach electric motor
Note: Note tightening
sequence.
• |
Insert connecting sleeve (3) between motor and pump
|
• |
Screw in 2x flange bolts (2)
|
• |
Screw in earth screw (1)
|
• |
Tighten 2x flange bolts 6 Nm
|
• |
Tighten earth screw 6 Nm
|
|
|
|
7. |
Attach hydraulic fluid reservoir (CS Speed oil)
• |
Insert new seal ring (2) in high-pressure pump
|
• |
Connect reservoir to high-pressure pump
|
• |
Tighten 2x bolt (1) 10 Nm
Note: Note differing