Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Component
|
- Ignition OFF
- Disconnect wiring harness connector from:
S255 Switch - Minimum Capacity, Washer Fluid
- Ignition ON
Data List
- Select the following Functional System on the diagnostic tester:
Instrument
- Check the following data list parameters:
Washer Level Switch
Note:
This data list parameter is in the data list 4 .
|
Low
|
|
|
T002
|
Check: Component
|
- Ignition OFF
- Connect fused jumper wire to:
S255 Switch - Minimum Capacity, Washer Fluid Wiring harness connector (wiring harness side) terminal 2 & S255 Switch - Minimum Capacity, Washer Fluid Wiring harness connector (wiring harness side) terminal 1
- Ignition ON
Data List
- Select the following Functional System on the diagnostic tester:
Instrument
- Check the following data list parameters:
Washer Level Switch
Note:
This data list parameter is in the data list 4 .
|
Normal
|
|
|
T003
|
Check: Circuit Interruption of Ground Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
S255 Switch - Minimum Capacity, Washer Fluid Wiring harness connector (wiring harness side) terminal 1 & Ground
|
less than 5 Ohm
|
|
|
T004
|
Check: Interruption of Signal Circuit
|
- Disconnect wiring harness connector from:
X125 Underhood Electronic Module
- Measure resistance between the following terminals:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 16 (XE1) & S255 Switch - Minimum Capacity, Washer Fluid Wiring harness connector (wiring harness side) terminal 2
|
less than 5 Ohm
|
|
|
T005
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
X125 Underhood Electronic Module
- Measure resistance between the following terminals:
S255 Switch - Minimum Capacity, Washer Fluid Wiring harness connector (wiring harness side) terminal 2 & Ground
|
greater than 500 kOhm
|
|
|