Quick Check F5:Actuator Test IMMO.SIG. TEST > < Quick Check F5:Actuator Test AIR CONTR. SOL

Multec- S X 14 XE / X 16 XE(L)        Quick Check F5:ACTUATOR TEST

 

SEC. AIR P.REL

 

Conditions for Checking

Nominal Value

Affected terminals:                   A10

Possible trouble codes:             52, 53

 

Ignition ON

Engine OFF

 

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES. Follow the instructions in the TECH 1 display.

 

 

Note:

The secondary air pump is actuated constantly.

The check is completed after a maximum of 10 s.

If the secondary air pump does not operate, the thermal protection switch in the pump may have interrupted the circuit. In this case, allow engine to cool down and then repeat test.

changes from

INACTIVE

to

ACTIVE

Noise check:

Secondary air injection in engine compartment audible

 

 

Notes on Trouble-shooting:

Nominal Value:

Cause of fault:

(If nominal value is not attained)

 

·   Remedy according to data list no. 22 SEC.AIR PUMP REL

 

 

 

 

 

 

 

 

 

Quick Check F5:Actuator Test IMMO.SIG. TEST > < Quick Check F5:Actuator Test AIR CONTR. SOL