Battery / Starter, Petrol (Current
Measurement)
Objective:
Evaluation of the battery charge and the current supply to the
battery as well as the operation of the starter.
Measurement:
Plot of the starter current during the start procedure.
Preparation:
Use multimeter function to adjust current probe to zero. Engine
oil temperature greater than
20°C . Turn off engine, turn off the ignition, turn off
all electrical loads.
Connections:
INPUT A
|
COM/TRIGGER
|
INPUT B
|
Clamp the current probe around all of the positive leads on the
battery, pointing the plus sign on the current probe towards the
positive pole or clamp the current probe around all of the negative
leads on the battery, pointing the negative sign on the current
probe towards the negative pole. Select the 1 mV/A measurement
range.
|
|
|
Procedure Tech 31:
1. |
Download Reference curve. |
2. |
Start engine. |
Reference Curve:
|
|
Procedure Tech 32:
1. |
Download Setup file (the Tech 32 uses only Setup
files, no reference curves). |
2. |
Start engine. |
Setup File:
Reference Curve:
|
|
|