vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Tank Ventilation Valve > < Electric Fuel Pump, Remove and Install

Fuel Vapour Separator, Remove and Install

Note:   Fuel escapes – observe safety measures and national legislation.

  Remove

1.   Remove fuel filler pipe
Note:   Vent hose remains attached to fuel filler pipe, do not disconnect degassing hose from rear degassing line.
2.   Detach degassing hoses (1) and (3) from fuel vapour separator (2)
Note:   Observe arrangement and laying of the degassing hoses.
3.   Remove fastening bolt (arrow) and fuel vapour separator from fuel filler pipe.
4.   Press fuel vapour separator off fuel filler pipe upwards.
Note:   Only for Combo
Object Number: 2410191  Size: DEFAULT


  Install

5.   Attach fuel vapour separator to fuel filler pipe with fastening bolt
6.   Push degassing hoses on to port on fuel vapour separator
Note:   Observe arrangement and laying of the degassing hoses.
7.   Clip fuel vapour separator on to fuel filler pipe
Note:   Only for Combo.
8.   Install fuel filler pipe

Tank Ventilation Valve > < Electric Fuel Pump, Remove and Install