vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F0: DATA LIST - Test Step 20 RECLINER MOTOR > < F0: DATA LIST - Test Step 18 RECLINER SWITCH

F0:DATA LIST

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

19

RECLINER POS.

Ignition ON

Press rocker switch for backrest forwards/ backwards forwards and then backwards

 

 

13 %         0.14 V

to

94 %         4.67 V

 

12

3, 4, 5
5-pin plug

 

 

 

Note:

The value displayed alters constantly within the specified range depending on the programmed end stops. The backrest moves forwards and backwards.

If the motor is already at one of the two end stops, the motor will only move again (i.e. the TECH 1 display will only change again) when the above rocker switch is pressed in the other direction.

 

 

 

 

 

 

 

 

 

 

 

 

The potentiometer and motor M72.4 for the backrest adjustment are connected to control unit K103 by a 5-pin plug with the designation "backrest". The potentiometer is wired with the three plug terminals designated (x) and the motor is wired with the two plug terminals designated (y).

 

Notes on Trouble-shooting:

Nominal Value:

Cause of fault:

(If nominal value is not attained)

 

·   Ignition OFF, disconnect battery negative terminal

·   Remove driver's seat

·   Release 5-pin plug "backrest" and disconnect from control unit K103

·   Using multimeter, measure resistance in 5-pin plug between Ter. 3 (x) and Ter. 1 (x)

 

approx. 10 kW

 

·   Potentiometer for motor M72.4 "backrest" defective (resistance path interrupted)

·   Lead interruption between potentiometer for M72.4 and 5-pin plug Ter. 3 (x) and Ter. 1 (x)

·   Lead short circuit between 5-pin plug Ter. 3 (x) and Ter. 1 (x) to potentiometer for M72.4

 

 

·   Using multimeter, measure resistance in 5-pin plug between Ter. 2 (x) and Ter. 3 (x)

 

between 1 kW and 10 kW, depending on "backrest adjustment"

·   Lead interruption between 5-pin plug Ter. 2 (x) and slider connection of potentiometer for M72.4

·   Potentiometer for M72.4 defective (slider has no contact)

·   Lead short circuit between 5-pin plug Ter. 3 (x) and Ter. 2 (x) to potentiometer for M72.4

 

 

 

 

 

 

 

 

 

 

 

 


Related Literature Units
-F2: TROUBLE CODE TABLE - Trouble Code 12 RECLINER CIRCUIT

F0: DATA LIST - Test Step 20 RECLINER MOTOR > < F0: DATA LIST - Test Step 18 RECLINER SWITCH