vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F0: DATA LIST - Test Step 12 MOTOR CURRENT > < F0: DATA LIST - Test Step 09 CLOSED/REF. POS.

Electronically Controlled Sliding Roof    Quick Check F0: Data List

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

11

S. ROOF MOTOR SP.

Ignition ON, engine running at idle speed

 

Turn control switch counterclockwise to stop

Electric motor lifts sliding roof

 

Control switch in "closed" position

Electric motor lowers electric sliding roof

 

Turn control switch clockwise to stop

Electric motor opens electric sliding roof

 

Control switch in "closed" position

Electric motor closed electric sliding roof

 

Note:

If the actual value lies below the minimum speed, there is a defect / dirt in the mechanism.

If necessary, clean mechanism, repeat check. Determine values over a defined period of time.

0 rpm

 

 

 

50 to 260 rpm

 

 

50 to 260 rpm

 

 

100 to 260 rpm

 

 

100 to 260 rpm

-

-

 

 

 

 

 

 

 

 