Test Step
|
Test
Equipment
Multimeter
|
Test
|
Notes
|
Nominal Value
|
|
|
MKM - 587 - A
|
of
|
between
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Radiator fan relay K51
|
|
|
|
|
|
31
|
|
Function, radiator fan relay K51
|
|
|
· Disconnect
wiring harness plug from coolant temperature switch S29 and bridge contacts.
· Ignition
off
|
Radiator fan motors M4 and M11
start operating
|
|
|
|
|
|
|
· Measure only if
function is not OK.
|
|
|
|
Voltmeter
range
20 V, DC
|
Voltage supply, radiator fan relay K51
|
K51 / Ter. (2)
K51 / Ter. (4)
K51 / Ter. (6)
|
Ground
Ground
Ground
|
· Remove
radiator fan relay K48.
· Disconnect
wiring harness plug from coolant temperature switch S29 and bridge contacts.
· Ignition
off
|
»
11,5 V
»
11,5 V
»
11,5 V
|
|
|
|
|
K51 / Ter. (8)
K51 / Ter. (6)
|
Ground
Ground
|
· Remove
radiator fan relay K48.
· Disconnect
wiring harness plug from coolant temperature switch S29 and bridge contacts.
· Ignition
on
|
»
11,5 V
»
0 V
|
|
|
Possible cause of fault, trouble - shooting:
1 Fuse F50 defective.
2. Fuse F52 defective.
3. Lead interruption between
K51 / Ter. (6) and coolant temperature switch S29 / lead BRGE.
4. Coolant temperature switch
S29 (see S29).
5. Lead interruption between
coolant temperature switch S29 / lead BR and ground.
6. Lead interruption between
K51 / Ter. (2) and fuse output F50.
7. Lead interruption between
K51 / Ter. (4) and fuse output F52.
|
|
() Terminal in wiring harness plugs
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|