Caution
Fuel escapes, observe safety regulations and national
legislation. Depressurise fuel using Fuel Pressure Gauge
KM-J-34730-91 via test connection (1) – collect escaping fuel
in suitable container.
Remove
Detach vacuum hose (2) and fastening clamp from fuel pressure
regulator (3) and carefully remove fuel pressure regulator from
fuel distributor pipe – ensure utmost cleanliness.
Caution
Damaged seal rings must be replaced.
|