vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F6: ADJUSTMENTS - No. 01 IDLE SPEED > < F5: ACTUATOR TEST - No. 04 IDLE AIR CONTR

Motronic M 1.5.4    Quick Check F5: ACTUATOR TEST

 

EGR PULS. RATIO

 

Conditions for Checking

Nominal Value

 

Affected Terminals: 23, 19

Possible Trouble Codes: 33, 34

 

This check can be performed in two operating conditions: "ignition ON, engine OFF" or "engine running at idle speed".

The first part of the check should be performed if the engine cannot be started; otherwise the second part ensures accurate diagnosis.

 

Check 1:

 

Ignition ON

 

Engine OFF

 

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES.

Follow the instructions in the TECH 1 display.

Note:

The exhaust gas recirculation valve is actuated at a frequency of 0.5 Hz.

The check is completed after a maximum of 30 s.

 

 

The exhaust gas recirculation valve switched alternately:

ACTIVE

INACTIVE

 

Noise check:

clicking noise from exhaust gas recirculation valve

 

Check 2:

 

Engine running at idle speed

 

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES.

Follow the instructions in the TECH 1 display.

 

Note:

The exhaust gas recirculation valve is actuated at a frequency of 0.5 Hz, which switches it on and off.

The check is completed after a maximum of 30 s.

 

The TECH 1 display

shows alternately

0 %

43 %

During the check, the

engine speed oscillates

 

 


Related Literature Units
-F2: TROUBLE CODES - Trouble Code 33 EGR VALVE VOLTAGE LOW
-

F6: ADJUSTMENTS - No. 01 IDLE SPEED > < F5: ACTUATOR TEST - No. 04 IDLE AIR CONTR