vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F8: ECU CONTROL - No. 04 SELECT CONTROL CONTROLLED EGR > < F6: ECU ADJUSTMENT - No. 03 SELECT ADJUSTMN. IAC BLM RESET

Table 8, F8: ECU CONTROL

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

01

SELECT CONTROL

RPM CONTROL

Engine running at idle speed

 

Engine throttle valve CLOSED

(accelerator pedal in idle position)

 

Vehicle stationary

 

Vehicles with AT:

Selector lever in "P" "N" position

 

Press key F8 in the system main menu, select the desired test using the arrow keys and confirm with YES.

Follow the instructions in the TECH 1 display.

 

-

-

-

 

 

Note:

In this mode, it is possible to increase / lower the engine idle speed in the range from 640 to 1760 rpm using the arrow keys.

In addition, the YES and NO keys can be used to display the various data list parameters. Key F9 is used to store the data as in the snapshot mode.

 

In this control mode, TECH 1 specifies the previously adjusted engine speed to the control unit and the control unit regulates the engine to this engine speed.

 

 

 

 

 

 

This mode should be used if it appears necessary to evaluate the various engine parameters (e. g. 02 INTEGRATOR or INJECTION PULSE) at increased or decreased idle speeds.

When this test is completed, the engine may stall. This may especially be the case if the radiator fan is running or other consumers are switched on. The snapshot data recorded by TECH 1 is however retained.

 

 

 

 

Notes on Trouble - shooting:

Nominal Value:

Cause of Fault:

·  See FO: DATA LIST, test step 27, 28

·   See F5: ACTUATOR TEST, test step 04

 

 

 

 

 


Related Literature Units
-F0: DATA LIST - Test Step 27 MIN DESIRED IDLE
-
-