vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F5: ACTUATOR TEST - No. 11 SELECT ACTUATOR SEC. AIR P.REL. > < F5: ACTUATOR TEST - No. 09 SELECT ACTUATOR INT. MANIF. V2

F5: ACTUATOR TEST

 

No.

TECH 1-Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

10

SELECT ACTUATOR EGR PULS. RATIO

Check information:

Carry out check 1 if the engine does not start; otherwise proceed to check 2 (check of exhaust gas recirculation system).

 

33, 34, 132

23, 50, 19

 

 

Check 1 (check of exhaust gas recirculation valve):

 

Ignition ON

Engine OFF

 

The exhaust gas recirculation valve switches alternately:

INACTIVE

ACTIVE

 

 

 

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES.

Follow the instructions in the TECH 1 display

 

Note:

The exhaust gas recirculation valve is actuated at a frequency of 0.5 Hz (actuation duration 1 s).

The check is completed after a maximum of 30 s.

Noise check:

clicking noise from exhaust gas recirculation valve

 

 

 

 

 

Check 2 (check of exhaust gas recirculation system):

The TECH 1 display shows alternately

EGR PULSE RATIO

 

 

 

 

Engine running at idle speed, operating temperature

0 %

50 %

EGR POS. FDBK

 

 

 

 

Throttle valve CLOSED (acccelerator pedal in idle position)

0.7 V

1.41 V

 

 

 

 

 

Vehicle stationary

 

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES.

Follow the instructions in the TECH 1 display.

 

Note:

The exhaust gas recirculation valve is actuated at a frequency of 0.5 Hz (actuation duration 1 s).

The check is completed after 5 cycles have been switched.

 

During the test, the engine speed may oscillate.

 

 

Notes on Trouble - shooting:

Nominal Value:

Cause of Fault:

·   Ignition ON

·   Using multimeter, measure voltage at plug of exhaust gas recirculation valve Y 18 / Ter. E to ground

11.5 to 13.5 V

·   Lead interruptions from control unit K 61 / Ter. 37 or from injectors relay K 43 / Ter. 8 to exhaust gas recirculation valve Y 18 / Ter. E

·   Ignition OFF

·   Disconnect control unit K 61 from wiring harness

·   Using multimeter, check from plug of exhaust gas recirculation valve Y 18 / Ter. A to control unit K 61 / Ter. 23 for passage and short circuit to ground

 

W

·   Short circuit or lead interruption from exhaust gas recirculation valve Y 18 / Ter. A to control unit K 61 / Ter. 23

Nominal values are attained

 

·   Mechanical part of exhaust gas recirculation valve defective

·   Electrical part of exhaust gas recirculation valve defective

·   Control unit K 61 defective

 

 

 

 

 


Related Literature Units
-TABLE 2, TROUBLE CODES - Trouble Code 33 EGR VALVE VOLTAGE LOW
-
-

F5: ACTUATOR TEST - No. 11 SELECT ACTUATOR SEC. AIR P.REL. > < F5: ACTUATOR TEST - No. 09 SELECT ACTUATOR INT. MANIF. V2