· Intake
air temperature lower than - 37 °C / 35 °F
(short circuit to battery
voltage or circuit interruption)
· Above
condition must be fulfilled for at least 1.0 s
Replacement values:
· 5 °C /
41 °F
Effects:
· All
adaptation except knock and throttle valve adaptation is blocked
· The
tank vent valve regulation is blocked
· The
tank vent valve is actuated to a minimum value
|