· On ignition "ON", the fault
is recognised immediately
· Voltage control relay can be actuated,
i.e.
trouble codes 62, 63 or 64 not set
· The circuit routed to the relevant
control unit output
(terminal
45 and/or 54) is open
· The fault must be recognised at least 8
times (160 ms)
· The circuit routed to the relevant
control unit output
(terminal
45 and/or 54) is open
Effects:
· Solenoid valves (brake band,
1-2/3-4 shift, 2-3 shift, torque converter clutch) and electro-hydraulic
pressure regulator are switched off
· On fault recognition, the
following individual gears can still be shifted manually (emergency program):
"Driving
stage" (gear) "D"(4), "3"(4), "2"(3),
"1"(1)
|