Disconnect rubber seal (1) from plenum chamber. Open service aperture (2). Disconnect wiring harness plug from heater element temperature sensor (3). Detach add-on heater temperature sensor (3) with bracket (4) from clean air filter housing. Unclip heater element temperature sensor from retaining clips (arrows).
Install, Connect Clip add-on heater temperature sensor in bracket. Attach heater element temperature sensor to clean air filter housing together with bracket. Connect wiring harness plug to heater element temperature sensor. Close service aperture. Attach rubber seal. |