Reference Gap Between Crankshaft Pulse Pickup and Increment Disc, Check (X 16 SZR)
Measure
Measure distance between crankshaft pulse pickup and increment disc with feeler gauge.
Nominal value: 1.0 ± 0.7 mm.
The crankshaft pulse pickup bracket must be replaced if the reference gap is not correct.
Tighten (Torque)
Attach crankshaft pulse pick-up bracket to oil pump housing - tightening torque 6 Nm / 4 lbf. ft.