Reference Gap between Crankshaft Pulse Pick-up and Increment Disc, Check (X 18 XE1)
Measure
Measure distance between crankshaft pulse pickup and increment disc with feeler gauge.
Nominal value: 1.0 ± 0.7 mm.
The oil pump must be replaced if the reference gap is not correct.
Tighten (Torque)
Attach crankshaft pulse pick-up to oil pump housing - tightening torque 8 Nm / 6 lbf. ft.