Workshop Manuals Factory service & repair Volkswagen
01 4-cylinder diesel engine (2.0 l engine, common rail)02 4-cylinder injection engine (2.0 l direct injection engine, turbocharger)03 Fuel supply system - Petrol engines04 Fuel supply system - Diesel engines05 Transfer box and final drive06 6-speed manual gearbox 0C607 8-speed automatic gearbox 0CM08 Running gear: Guide for using trailers09 Wheels and Tyres Guide - General Information10 Running gear: Guide for increasing and decreasing load ratings11 Wheels and Tyres Guide12 Brake systems13 Running gear, axles, steering14 Heating, air conditioning15 Heating and air conditioning: Auxiliary heater16 Electrical System, General Information17 Electrical system18 Electrical: Communication19 General body repairs, exterior20 General body repairs, interior
Volkswagen Amarok 2H (2010-2020)18 · Electrical: Communication
18 · Electrical

Preparatory measures for calibration

Make
Volkswagen
Model
Amarok 2H
Year
2010–2020
Section
Reversing camera system › Preparatory measures for calibration
Electrical: CommunicationPreparatory measures for calibration

Preparatory measures for calibration

Electrical system, General information

Reversing camera system may have to be recalibrated following repair work on the vehicle. In detail, this is the case after:

  • Removing and installing reversing camera
  • Renewing reversing camera system control unit
  • Accident repairs on rear lid
  • After vehicle alignment
  • Repairs to front or rear axle

Extensive preliminary work is required before actual calibration can be carried out using vehicle diagnostic tester. This is described in the following.

Special tools and workshop equipment requiredCalibration unit VAS 6350
W00-10488

For calibration, vehicle must be positioned on a horizontally, firm and level surface. Nobody may be inside vehicle during measurement. Vehicle must not be moved during measurement. Opening and closing the vehicle doors must be avoided. On camera image in vehicle interior, check whether all calibration device markings are easy to identify and not disturbed by light influences or reflections.

Connect vehicle diagnostic testerElectrical system, General informationRep. gr.97Vehicle diagnosis, testing and information systems; Connecting vehicle diagnostic tester.

Set steering wheel sender G85 to wheels-straight-ahead position.

Switch on ignition and engage reverse gear. This activates the reversing camera system.

Note

  • Ensure that reversing camera has free visibility on calibration platform Item.

Overview of assembled measuring facility:

N91-11991
  • Wheel centre mounting VAS 6350/1
  • Wheel centre mounting VAS 6350/1
  • Right angle for mounting measuring unit for distance measurement
  • Calibration unit VAS 6350/4
    Distance between angle brackets of calibration device (Item or Item) and paddles on wheel centre mountings of rear wheels: 1.75 m (dimension A).
  • Linear laser VAS 6350/3
    Switching on and off Owner's manual
  • Plastic foot
    Total of three on bottom of measuring equipment.
    Adjustable to adjust horizontal position of measuring facility
  • Spacing laser VAS 6350/2
    Notes on operation Owner's manual
  • Hole for determining the height of the floor plate.
  • Spirit level on measuring facility
    To check horizontal position of measuring facility
  • Left angle for mounting measuring unit for distance measurement

Secure three wheel bolt adapters in each corresponding hole circle of wheel centre mounting.

Fit the paddles on the two wheel centre mountings and secure them with the clamping nuts.

Fit the wheel centre mountings onto the wheel bolts on the rear wheels. Wheel centre mountings are positioned and secured in the adapters through »O-rings«.

N94-10685

Note

  • Fit wheel centre mountings on wheels in such a way that no »anti-theft wheel bolts«, if any, are connected to wheel bolt adapters.

Set paddles with the help of the clamping nuts in such a way that they can move freely just above the floor.

Note

  • The paddles must be free to move and must be able to swing to vertical position.

Position the calibration unit VAS 6350/4 at a distance of 1.75 m behind vehicle. Set distance between angle brackets of calibration unit and paddles on wheel centre mountings of rear wheels to (dimension A), as shown in the illustration Item.

Align calibration unit VAS 6350/4 into the horizontal position. Do this by turning the plastic feet under the calibration unit until the air bubble in the spirit level is precisely in the centre of the indicator (arrow).

N94-10686

Press pushbutton (1) to switch the laser VAS 6350/2 to the measuring method whereby the length of the laser's housing is not measured at the same time. This is the case when the arrow (2) is shown in the indicated position on the display.

N94-11800

Fit laser VAS 6350/2 vertically onto the measurement hole (arrow) to determine the height of the floor plate.

N94-11799

Make a note of the displayed value. Later in the procedure the tester will prompt you to enter this value.

Measure the reversing camera height (a) from the middle of the camera lens to the ground. Make a note of the displayed value. Later in the procedure the tester will prompt you to enter this value.

N91-11993

Install laser (2) centrally on back edge of calibration unit VAS 6350/4.

N91-11992

Switch on the laser (2) on the calibration unit. Align the whole calibration unit so that the laser beam (1) is focused on the rear of the vehicle in the centre above the VW badge.

Switch on spacing laser VAS 6350/2 for distance measurement by pressing the ON button. The following display appears and the laser is activated:

N94-10681

Hold the spacing laser for distance measurement (2) on one side of the calibration unit flush in the bracket. The spacing laser must be firmly in contact with the bracket.

N94-10684

Ensure that laser beam from spacing laser for distance measurement hits lower, enlarged part of paddle (1).

N94-10684

If this is not the case, adjust paddles accordingly on wheel mounting using clamping bolts.

With one hand, hold the spacing laser for distance measurement firmly in the bracket on the measuring facility. Now, briefly press ON button to measure distance. The following appears in the display:

N94-10682

The distance is shown on the display in “metres”.

Make a note of the distance.

Repeat measuring process in same manner for other rear wheel on other side of calibration unit.

Measured distance value must be identical on both sides. If the value is not identical, adjust calibration unit until values on both sides are identical and the distance is 1.75 m.

When adjusting the calibration unit, ensure that the laser beam of the spacing laser continues to hit the vehicle centrally above the VW logo and that the spirit level indicator remains in the centre. If necessary, readjust accordingly.

The value for the measured distance must be entered during calibration in vehicle diagnostic tester in “millimetres”.

Calibrating reversing camera system → Chapter

Parts & tools for this job For 2010 Volkswagen Amarok

As an Amazon Associate we earn from qualifying purchases.