Workshop Manuals Factory service & repair Volkswagen
01 4-cylinder diesel engine (2.0 l engine, common rail)02 4-cylinder injection engine (2.0 l direct injection engine, turbocharger)03 Fuel supply system - Petrol engines04 Fuel supply system - Diesel engines05 Transfer box and final drive06 6-speed manual gearbox 0C607 8-speed automatic gearbox 0CM08 Running gear: Guide for using trailers09 Wheels and Tyres Guide - General Information10 Running gear: Guide for increasing and decreasing load ratings11 Wheels and Tyres Guide12 Brake systems13 Running gear, axles, steering14 Heating, air conditioning15 Heating and air conditioning: Auxiliary heater16 Electrical System, General Information17 Electrical system18 Electrical: Communication19 General body repairs, exterior20 General body repairs, interior
Volkswagen Amarok 2H (2010-2020)16 · Electrical System, General Information
16 · Electrical

Preserving threaded electrical connections

Make
Volkswagen
Model
Amarok 2H
Year
2010–2020
Section
Cleaning contact surfaces › Preserving threaded electrical connections
Electrical System, General InformationPreserving threaded electrical connections

Preserving threaded electrical connections

Warning Missing anti-corrosion treatment results in damage to the onboard supply.

Note

  • All threaded connections must be tightened to specified torque.
  • Always use hose supplied with anticorrosive agent tin.
  • Use protection wax for cold area.
  • Use cavity sealing agent for warm area.
  • The sealing agent independently reaches the respective points through capillary action.

Hold nozzle under ring terminal and spray all around stud.

N97-10794

Fit nozzle over ring terminal and spray all around stud and ring terminal.

N97-10795