CAUTION! 

Part numbers are for reference only. Always check with your Parts Dept. for the latest parts information.

When inspecting grounds 607-609 in plenum:

-

Check that sound deadener for plenum does not interfere with seating of terminal separator.

If deadener interferes:

-

Cut/scrape away any interfering deadener as necessary.

-

Cover stud and paint exposed metal surrounding stud

Note: 

DO NOT paint stud threads or terminal seating surface.

-

Inspect each grounding stud (should be free of paint and weld splatter). Contact surface must be clean and bright.

-

Apply Stabilant 22A to ground terminals and carefully install ground terminals onto stud so that each terminal is in a different slot on the plastic
separator as shown.

Note: 

Make sure separator fits over stud correctly and will not interfere with first wire terminal and base of grounding stud.