Main fuses OK.

-

Fuses No.29, 32, 34 and 43 OK.

Prerequisites (with air conditioning)

-

Vehicle at room temperature, warmer than +15 °C (59 °F)

-

A/C on

-

Lowest temperature setting and highest blower speed

NOTE:

-

Activation of individual control elements is limited to 30 secs. but can be stopped at any time by pressing -> button.

-

Final controls are checked acoustically or by touching.

-

Ignition must be switched off before repeating Output Diagnostic Test Mode.

Work sequence

-

Connect Scan Tool (ST) V.A.G 1551/(VAG 1552).

-

With engine idling, select Engine Control Module (ECM) with "Address word" 01. 

Indicated on display:

Rapid data transfer

HELP

Select function XX

-

Operate Scan Tool (ST) and advance through program sequence by following display.

-

Press buttons -0- and -3- for "Output Diagnostic Test Mode" (DTM).

Activating Cold Start Injector -N108-:

Indicated on display:

Component Tests and General Diagnostics|Page 3518 > < Component Tests and General Diagnostics|Page 3516