Note
- Releasing refrigerant into the environment is a punishable offence.
- All components of the refrigerant circuit which have been opened must be sealed with suitable plugs to prevent moisture intrusion.
Unscrew cap (3).

Warning Danger of freezing injuries.
If refrigerant circuit has not been evacuated, refrigerant and refrigerant oil will escape.
Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in coolant circuit due to re-evaporation. Extract refrigerant again.
Evacuate refrigerant circuit, e.g. with air conditioner service station VAS 6007A (or successor model) before renewing valve (2).
Unscrew valve core (2) (2 ± 0.2 Nm) out of refrigerant line using suitable adapter (4). When doing this, carefully hold valve support (1) with a suitable tool.
Install in reverse order.