Heating and air conditioning: Auxiliary heaterPreheating mode
Preheating mode
Once the coolant temperature has reached 84 ℃, the control unit switches to the energy-saving part load mode. If the coolant temperature continues to rise above 88 °C, the control unit switches to the controlled waiting period. If the coolant temperature does not drop below 76° C within 900 seconds during the controlled waiting period, the heater unit will start with the normal start procedure in full-load mode when the coolant temperature does drop below 76° C.