Workshop Manuals Factory service & repair Volkswagen
01 3-cylinder direct-injection engine (1.0 l engine, 4V, EA 211)02 4-cylinder injection engine (1.2 l direct injection engine, turbocharger)03 4-cylinder injection engine (1.4 l direct injection engine, turbocharger)04 4-cylinder injection engine (1.4 l engine, natural gas)05 4-cylinder common rail engine (2.0 l, 4V, turbocharger)06 Fuel supply system - Petrol engines07 Fuel supply system - Diesel engines08 Fuel supply system - natural gas engines09 4-cylinder diesel engine (2.0 l engine, common rail, generation II)10 4-cylinder diesel engine (1.6 l engine, common rail)11 4-cylinder injection engine (1.6 l engine, 4 valves, MPI)12 5-speed manual gearbox 0A413 5-speed manual gearbox 0AH14 6-speed dual clutch gearbox 02E15 7-speed dual clutch gearbox 0AM16 6-speed manual gearboxes 02Q and 0BB17 Propshaft and rear final drive18 6-speed manual gearbox 02S19 Running gear: Guide for using trailers20 Wheels and Tyres Guide - General Information21 Brake systems22 Running gear, axles, steering23 Wheels and Tyres Guide24 Heating, air conditioning25 Supplementary heating26 Electrical System, General Information27 Electrical system28 Electrical: Communication29 General body repairs, interior30 General body repairs, exterior
Volkswagen Caddy Mk4 (2015-2020)24 · Heating, air conditioning
24 · Heating & A/C

Safety precautions when handling refrigerants

Make
Volkswagen
Model
Caddy Mk4
Year
2015–2020
Section
Notes on safety › Safety precautions when handling refrigerants
Heating, air conditioningSafety precautions when handling refrigerants

Safety precautions when handling refrigerants

Risk of freezing injury caused by refrigerant

When working on the air conditioning system, there is a risk of highly pressurised refrigerant escaping from the system. There is a risk of injury to the skin and parts of the body due to freezing.

Wear protective gloves.

Wear eye protection.

Extract refrigerant, and open the refrigerant circuit immediately afterwards.

If more than 10 minutes have passed since the refrigerant was extracted, repeat the extraction process before opening the refrigerant circuit. Due to re-evaporation, pressure will be built up in the refrigerant circuit.

Risk of damage to refrigerant lines

There is a risk of damage to the refrigerant lines due to rupture of the inner foil.

Never bend refrigerant lines to a radius less then 100 mm (r < 100 mm).

Parts & tools for this job For 2015 Volkswagen Caddy

As an Amazon Associate we earn from qualifying purchases.