When working on the air conditioning system, there is a risk of highly pressurised refrigerant escaping from the system. There is a risk of injury to the skin and parts of the body due to freezing.
Wear protective gloves.
Wear eye protection.
Extract refrigerant, and open the refrigerant circuit immediately afterwards.
If more than 10 minutes have passed since the refrigerant was extracted, repeat the extraction process before opening the refrigerant circuit. Due to re-evaporation, pressure will be built up in the refrigerant circuit.
There is a risk of damage to the refrigerant lines due to rupture of the inner foil.
Never bend refrigerant lines to a radius less then 100 mm (r < 100 mm).
Parts & tools for this job For 2015 Volkswagen Caddy
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Caddy 2015 cabin filter