Removing and installing expansion valve
- Make
- Volkswagen
- Model
- CC Passat CC and CC
- Year
- 2008–2016
- Section
- Refrigerant circuit › Removing and installing expansion valve
Removing and installing expansion valve
Special tools and workshop equipment requiredAir conditioner service stationHose clip pliers VAS 6340
Note
- The refrigerant must be extracted beforehand, with the air conditioning service station.
- The previously used air conditioner service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
- To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
Observe safety precautions Chapter“Safety precautions when handling refrigerants”.
Comply with notes Chapter“Working on refrigerant circuit”.
Note
- Depending on engine, the charge air pipe or charge air hose must be removed.
Warning The cooling system remains pressurised while the engine is warm!
Danger of scalding due to steam and hot coolant.
Reduce excess pressure by covering the cap of the coolant expansion tank with a cloth and opening it carefully.
Clamp off coolant hoses using hose clamps to 40 mm Ø VAS 3093.
Loosen hose clips using hose clip pliers VAS 6340 and disconnect coolant hoses to heat exchanger.
Remove nut (1) (4.5 Nm) and bolt (4) (2.5 Nm).

Release clips (2) and remove heat shield (3).

- Bolts
10 ± 1 Nm
Qty. 2 - Refrigerant lines on expansion valve
- O-ring
13.7 mm; 2.5 mm - Expansion valve
Removing:Extract refrigerant with air conditioning service station.WARNINGDanger from escaping pressurised refrigerant!Freezing of skin and other body parts.Extract refrigerant and then immediately open refrigerant circuit.If the refrigerant was extracted more than 10 minutes before the opening of refrigerant circuit, the refrigerant must be extracted again. The pressure in the circuit will increase due to subsequent evaporation.Unscrew bolts(1) and pull out refrigerant lines (2) from expansion valve.Remove bolts (8) and remove expansion valve. - O-ring
14 mm; 1.82 mm
Moisten with refrigerant oil when installing. - O-ring
10.8 mm; 1.82 mm
Moisten with refrigerant oil when installing. - O-ring
9.5 mm; 2.5 mm - Socket head combi-bolt
5 Nm
Install in reverse order.
- The expansion valve atomises incoming refrigerant and regulates the flow so that, depending on the heat transport, the vapour does not become a gas until it reaches the outlet of the evaporator.
Parts & tools for this job For 2008 Volkswagen CC
- PARTEngine gasket setSearch: Volkswagen CC 2008 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.