Safety precautions when handling refrigerants
When working on the air conditioning system, there is a risk of highly pressurised refrigerant escaping from the system. There is a risk of injury to the skin and parts of the body due to freezing.
Always wear safety gloves.
Always wear safety goggles.
Extract refrigerant, and open the refrigerant circuit immediately afterwards.
If more than 10 minutes passed since the refrigerant has been extracted, do not open the refrigerant circuit prior to extracting refrigerant anew. Due to re-evaporation, pressure will be built up in the refrigerant circuit.
There is a risk of damage to the refrigerant lines due to rupture of the inner foil.
Never bend refrigerant lines to a radius less then 100 mm (r < 100 mm).
Parts & tools for this job For 2008 Volkswagen CC
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen CC 2008 cabin filter