Crafter Mk1 (2006-2016): Heating and air conditioning: Auxiliary heater
Also for this vehicle: Crafter Mk2 (2017-2023).
Engine
Transmission
Steering & suspension
Brakes
Heating & A/C
Electrical
Body & interior
Choose Sections to see everything in a chapter, or a chapter title to start at its first page.
Engine
Transmission
Steering and suspension
Brakes
Electrical
Heating and air conditioning
- 16Heating and air conditioning: Auxiliary heaterHeating and air conditioning: Auxiliary heater: Sections
Hydronic D5WS auxiliary coolant heater12 pages
- Hydronic D5WS auxiliary coolant heater
- General notes
- Safety precautions
- Rules for cleanliness and important notes
- General notes
- Overview of fitting locations – Hydronic D5WS auxiliary coolant heater
- Assembly overview – Hydronic D5WS auxiliary coolant heater
- Notes on operation of Hydronic D5WS auxiliary coolant heater
- Control and safety devices of Hydronic D5WS auxiliary coolant heater
- Technical data of Hydronic D5WS auxiliary coolant heater
- Type and configuration of the Hydronic D5WS auxiliary coolant heater
- Technical data of the coolant circulation pump V50
Pre-selection clock of Hydronic D5WS E111 auxiliary coolant heater9 pages
- Pre-selection clock of Hydronic D5WS E111 auxiliary coolant heater
- Operation and function of pre-selection clock E111
- Setting, activating and deactivating pre-selected times
- Removing and installing pre-selection clock E111
- Diagnostic functions of the pre-selection clock E111
- Reading event memory using pre-selection clock E111
- Table of fault codes in event memory (fault codes 000 to 050)
- Table of fault codes in event memory (fault codes 051-091)
- Unlocking control unit and deleting event memory
Repair work on Hydronic D5WS auxiliary coolant heater23 pages
- Repair work on Hydronic D5WS auxiliary coolant heater
- Safety precautions
- General notes
- Assembly overview – heater unit of Hydronic D5WS auxiliary coolant heater
- Removing and installing heater unit with bracket
- Removing and installing bracket for heater unit
- Removing and installing seal (sealing foil)
- Removing and installing exhaust pipe
- Removing and installing blower cover
- Removing and installing housing cover
- Removing and installing auxiliary heater control unit J364
- Removing and installing glow plug for heater Q9
- Removing and installing fuel filler neck
- Removing and installing flame monitor G64
- Checking flame monitor G64
- Removing and installing coolant temperature sender for heater G241 and overheating sensor G189 (combination sensor)
- Checking coolant temperature sender for heater G241 and overheating sensor G189
- Removing and installing combustion air blower V6
- Checking combustion air blower V6
- Removing and installing flame protection mesh
- Removing and installing combustion chamber
- Removing and installing heat exchanger
- Removing and installing remote control receiver for auxiliary coolant heater R149
Coolant circuit with auxiliary heater9 pages
- Coolant circuit with auxiliary heater
- Schematic diagram - coolant hoses
- Coolant hose schematic diagram for vehicles with auxiliary heater and 4-cylinder engine
- Coolant hose schematic diagram for vehicles with auxiliary heater, auxiliary heat exchanger and 4-cylinder engine
- Coolant hose schematic diagram for vehicles with auxiliary heater and 4-cylinder engine, Euro 6
- Coolant hose schematic diagram for vehicles with auxiliary heater, auxiliary heat exchanger and 4-cylinder engine, Euro
- Coolant hose schematic diagram for vehicles with auxiliary heater and 5-cylinder engine
- Coolant hose schematic diagram for vehicles with auxiliary heater, auxiliary heat exchanger and 5-cylinder engine
- Functional description of vacuum water valves
Fuel supply to Hydronic D5WS auxiliary coolant heater7 pages
- Fuel supply to Hydronic D5WS auxiliary coolant heater
- Rules for cleanliness
- Assembly overview – fuel take-off
- Removing and installing metering pump V54 for Hydronic D5WS
- Removing and installing strainer of metering pump V54
- Prerequisites for checking/measuring fuel delivery rate
- Checking/measuring fuel delivery rate of Hydronic and »D5WS« auxiliary coolant heater
Auxiliary air heaters Airtronic D2 and D4S17 pages
- Auxiliary air heaters Airtronic D2 and D4S
- General notes
- Safety precautions
- Rules for cleanliness
- Overview of auxiliary air heaters installed in vehicles
- Working principles of Airtronic auxiliary air heaters D2 and D4S
- Control and safety devices of auxiliary air heaters Airtronic D2 and D4S
- Fitting location and principle of operation of Airtronic D2 auxiliary air heater
- Fitting location and principle of operation of Airtronic D4S auxiliary air heater
- Technical data of Airtronic D2 auxiliary air heater
- Technical data of Airtronic D4S auxiliary air heater
- Type and version of auxiliary air heaters Airtronic D2 and D4S
- Identification plate of Airtronic D2
- Identification plate of Airtronic D4S
- Synchronising remote control
- Setting or changing operating time of auxiliary heater
- Using remote control
Pre-selection clock E111 with temperature regulator on auxiliary air heaters Airtronic D2 and D4S, »05.201010 pages
- Pre-selection clock E111 with temperature regulator on auxiliary air heaters Airtronic D2 and D4S, »05.2010
- General notes
- Operation and function of pre-selection clock E111 with temperature regulator
- Setting, activating and deactivating pre-selected times, pre-selection clock E111 with temperature regulator
- Removing and installing pre-selection clock E111 with temperature regulator
- Pin assignment on rear of pre-selection clock E111 with temperature regulator
- Diagnostic functions of the pre-selection clock E111
- Table of fault codes in event memory of auxiliary air heaters Airtronic D2 and D4S (fault codes 000-050)
- Table of fault codes in event memory of auxiliary air heaters Airtronic D2 and D4S (fault codes 051-097)
- Unlocking control unit and deleting event memory
Pre-selection clock E111 with temperature regulator on auxiliary air heaters Airtronic D2 and D4S, 05.2010 »8 pages
- Pre-selection clock E111 with temperature regulator on auxiliary air heaters Airtronic D2 and D4S, 05.2010 »
- Operation and function of pre-selection clock E111 with temperature regulator
- Setting, activating and deactivating pre-selected times, pre-selection clock E111 with temperature regulator
- Removing and installing pre-selection clock E111 with temperature regulator
- Reading event memory using pre-selection clock E111
- Table of fault codes in event memory of auxiliary air heaters Airtronic D2 and D4S (fault codes 000-050)
- Table of fault codes in event memory of auxiliary air heaters Airtronic D2 and D4S (fault codes 051-099)
- Unlocking control unit and deleting event memory
Repair work on auxiliary air heaters Airtronic D2 and D4S25 pages
- Repair work on auxiliary air heaters Airtronic D2 and D4S
- General notes
- Assembly overview – heater unit of Airtronic D2 auxiliary air heater
- Assembly overview – heater unit of Airtronic D4S auxiliary air heater
- Overview of available versions of combustion air blower V6
- Removing and installing heater unit of Airtronic D2 auxiliary air heater
- Removing and installing housing with heater unit of Airtronic D4S auxiliary air heater
- Removing heater unit of Airtronic D4S auxiliary air heater from housing and installing it back in housing
- Removing and installing exhaust pipe of Airtronic D2 auxiliary air heater
- Removing and installing exhaust pipe of Airtronic D4S auxiliary air heater
- Removing and installing intake connecting pipe for intake air of Airtronic D2 auxiliary air heater
- Removing and installing intake connecting pipe for intake air, Airtronic D4S auxiliary air heater
- Removing and installing air distribution housing of Airtronic D4S auxiliary air heater
- Removing and installing air durct of Airtronic D4S auxiliary air heater
- Removing Airtronic auxiliary air heaters D2 and D4S from housing and installing them back in housing
- Mode of function of auxiliary heater control unit J364
- Removing and installing auxiliary heater control unit J364
- Removing and installing glow plug for heater Q9
- Removing and installing flame protection mesh
- Removing and installing flame monitor G64 and overheating sensor G189 (combination sensor)
- Checking flame monitor G64 and overheating sensor G189
- Removing and installing combustion air blower V6 (combination blower)
- Removing and installing heat exchanger
- Removing and installing combustion chamber
- Ambient temperature sensor 2 G249
Fuel supply to Airtronic auxiliary air heaters D2 and D4S7 pages
- Fuel supply to Airtronic auxiliary air heaters D2 and D4S
- Rules for cleanliness
- Assembly overview – fuel take-off
- Removing and installing metering pump V54
- Removing and installing metering pump V54 for Airtronic D2
- Removing and installing metering pump V54 for Airtronic D4S
- Checking/measuring fuel delivery rate of Airtronic auxiliary air heaters D2 and D4S
Body