Eos (1F7) V6-3.2L (BUB) (2008)
Air Injection Control Valve: Service and Repair
Secondary Air Injection Combination Valve, Checking
Procedure
-
Disconnect the secondary air hose - arrow - and connect the assisting hose to the hose leading to the secondary air combination valve.
-
Blow lightly into the assisting hose by mouth, do not use compressed air.
‹› Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to flush.
-
Blow more strongly into assisting hose by mouth, do not use compressed air.
‹› The AIR combination valve must open, it must be possible to flush.
-
If the switch point cannot be detected, replace the AIR combination valve. Refer to => [ Combination Valve ] See: Service and Repair.