Eos (1F7) V6-3.2L (BUB) (2008)
If the specifications was not obtained:
-
Replace the Leak Detection Pump (LDP) (-V144- ).
If the specified values are obtained:
Checking voltage supply
‹› The voltage for the Leak Detection Pump (LDP) (-V144- ) is supplied via the Power Supply Relay (terminal 30, B+) (J317).
-
Check the Leak Detection Pump (LDP) (-V144-) for voltage.
-
Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 to Ground (GND) for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
-
Switch the ignition off.
If the specified value was not obtained: