Do Not Sell My Personal Information
volkswagen Workshop Repair Guides

Volkswagen Workshop Manuals

< PREV PAGE NEXT PAGE >
Page 2
background image

-

Connect a Hand held remote control (jumper) to terminal - 1 - of the fuel delivery unit and to vehicle battery (+).

-

Connect a jumper cable from an Electrical connector test lead set to terminal - 5 - of the fuel delivery unit and to vehicle Ground (GND).

CAUTION!
Fuel system is under pressure! Before opening the system, place rags around the connection area. Then release the pressure by carefully
loosening the connection.

-

Disconnect fuel line - arrow - by pulling release button.

-

Connect the Fuel pressure test set (high pressure) onto the disconnected fuel supply line.

Powertrain Management > Fuel Delivery and Air Induction > Fuel Pump > Fuel Pressure > System Information > System Diagnosis > Fuel Pump Electrical, Testing > Page 3244