Quick-release coupling removal
- Make
- Volkswagen
- Model
- Fox Brazil: Fox, SpaceFox, CrossFox
- Year
- 2010–2015
- Section
- Coolant gas loop › Quick-release coupling removal
Quick-release coupling removal
Note
- After every removal, the sealing ring, locking insert and safety ring must be replaced.
Connect the Climate control recovery, recycling and refill set or VAS 6008 EQ 7098 or similar equipment to the service valves (1) and (2) of the cooling gas circuit and aspirate all the gas Air conditioning with R134a cooling gasRep. gr.00Technical data.

Note
- Contaminating the environment with refrigerant is a punishable offence.
- All refrigerant circuit components that are open must be closed with proper plugs to prevent humidity from entering them.
Displace the sealing boot (1) from the coupling of the refrigerant pipes (2), so that the assembly area is freed from the coupling.

Place disconnector (2) in the coupling segment. The cuts on the tool must be in line with the indicators.

Push disconnector (2) in the direction of (arrow A) into compressor pipes (1) against the stop of coupling (3).
Hold disconnector (2) on the stop and pull coupling (1) in the direction of (arrow).

After every removal, the sealing ring, locking insert and safety ring must be replaced.
Parts & tools for this job For 2010 Volkswagen Fox
- FLUIDCoolantSearch: Volkswagen coolant antifreeze
- PARTThermostatSearch: Volkswagen Fox 2010 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.