Leak control
- Make
- Volkswagen
- Model
- Fox 5Z, Europe
- Year
- 2005–2011
- Section
- Vacuum system - Check › Leak control
Leak control
Note
- Atmospheric air pressure is 1013 mbar at sea level (N.N.)
- Air pressure lowers as altitude increases (approx. 100 mbar/1000 m of altitude).
- Local and climate variations also affect vacuum generation.
- Cold engines, activated air conditioning systems, or simply an idling engine negatively affect vacuum generation.
Previously test all vacuum hoses for damages (e.g. cracks or “ruptures”) as well as proper fitting.
Connect the servo brake vacuum measurement device VAS 6721Chapter
Open closing valve (A) .
Close closing valves (B) and (C).

Operate the engine at service temperature (>60ºC); briefly press the gas pedal once (engine rotation greater than 2,000 rpm).
In normal circumstances (check indications), the generated vacuum must be between 600 and 950 mbar (depending on the engine).
Open closing valve (C) to evacuate the servo brake.

Stop the engine.
Read and register the indicated measurement.
Vacuum must lower by 400 mbar in 12 hours.
In case of greater vacuum drop, you must test the leakage point located in the region of the ...
Brake servoor Retention valve, vacuum hoses with connectors and intake manifold/vacuum pump.In case of major leaks, vacuum drops abruptly within a few seconds.
After generating vacuum, close the closing valve (A) , to test the servo brake vacuum system.

After generating vacuum, close the closing valve (C), to check the vacuum system of the servo brake vacuum measurement device VAS 6721 until the suction tube or vacuum pump.

To facilitate disassembly of adaptor and hose connections, open the closing valve (B) .
Parts & tools for this job For 2005 Volkswagen Fox
- PARTBrake padsSearch: Volkswagen Fox 2005 brake pads
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid