Removal
- Make
- Volkswagen
- Model
- Fox 5Z, Europe
- Year
- 2005–2011
- Section
- Plenum chamber (air conditioning) - remove and install › Removal
Removal
Connect the Climate control recovery, recycling and refill set or VAS 6008 EQ 7098 or similar equipment to the service valves (arrows) in the refrigerant circuit and aspirate all the gas Air conditioning with R134a refrigerantRep. gr.00Technical data.

Loosen the fastening screws (arrows) and remove refrigerant circuit tubing.

Warning Risk of burns!
With hot engine, the coolant temperature may be over 100°C.
Cooling system is pressurized.
Before starting any work, reduce pressure and temperature,
if required.
Close the coolant hoses in engine compartment by using the Clamps (diam. 25 mm) 3094

Release the clamps (arrows) with the Standard-type clamp pliers VW 5162 (VWB) - ou - VAS 5024A and remove the hoses.
Install a hose on one of the heat exchanger outlets. At the other outlet, place a container to collect coolant.
Use a compressed air pistol to remove the coolant from the heat exchanger.
Turn off the ignition and all electrical equipment, and remove the key from ignition.
Disconnect the Battery AElectrical devicesRep. gr.27 Starter motor, alternator, battery.
Remove the dash panel Body - Internal assembly worksRep. gr.70Lining / insulation.
Remove the direct support for the panel bracket Body - Internal assembly worksRep. gr.70Lining / insulation.
Remove the remaining fastening screws.
Before removing the housing, remove the evaporator, the heat exchanger and the expansion valve connections.
Remove the heater and cooling equipment.
Parts & tools for this job For 2005 Volkswagen Fox
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Fox 2005 cabin filter
As an Amazon Associate we earn from qualifying purchases.